Allen-Bradley 1756-EN2TR Communication Modules

نشر بتاريخ 2024-08-22 12:54 PM
Allen-Bradley 1756-en2tr/1756-EN2TR Communication Modules More models 1756-EN2TR 1756-EN2TP 1756-EN4TR 1756-EN2TRK 1756-EN2TSC 1756-EN3TR 1756-CMS1B1 1756-ENBT 1756-EN2F 1756-CN2R 1756-CNBRK 1756-L55M12 1756-M02AS 1756-RIO With optical interface No Supporting protocol for TCP/IP Yes Supporting protocol for DeviceNet No Supporting protocol for other bus systems No Redundancy Yes IO link master No Supporting protocol for DeviceNet Safety No Supporting protocol for EtherNet/IP Yes Power dissipation 5.1 W Thermal dissipation 17.4 BTU/h Enclosure type rating None (open-style) Ethernet ports 2 Ethernet RJ45 Category 5 CIP unconnected messages 128 + 128 (backplane + Ethernet) Current draw 1 A @ 5.1V DC, 3 mA @ 24V DC Ethernet cable 802.3 compliant shielded or unshielded twisted pair Wiring category 2 - on Ethernet ports, 3 - on USB ports Communication rate 10/100 Mbps Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for example, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.) Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC for 60 s Supporting protocol for LON No Supporting protocol for ASI No Supporting protocol for PROFIBUS No Supporting protocol for CAN No Supporting protocol for INTERBUS No Supporting protocol for KNX No Supporting protocol for Modbus No Supporting protocol for Data-Highway No Supporting protocol for SUCONET No With potential separation No Supporting protocol for SERCOS No Supporting protocol for INTERBUS-Safety No Radio standard Bluetooth No Radio standard Wi-Fi 802.11 No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for Foundation Fieldbus No Supporting protocol for PROFINET CBA No Supporting protocol for PROFINET IO No Supporting protocol for PROFIsafe No Supporting protocol for SafetyBUS p No Radio standard GPRS No Radio standard GSM No Radio standard UMTS No Slot width 1 ATEX temp code T4 For these requirements Select this interface Control I/O modules and drives Act as an adapter for I/O on remote EtherNet/IP links Communicate with other EtherNet/IP devices (messages and HMI) Bridge EtherNet/IP links to route messages to devices on other networks 1756-EN2F, 1756-EN2FK 1756-EN2T, 1756-EN2TK, 1756-EN2TXT 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT 1756-EN2TR, 1756-EN2TRK, 1756-EN2TRXT 1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT 1756-ENBT, 1756-ENBTK Support Device Level Ring (DLR) and linear topologies 1756-EN2TR, 1756-EN2TRK, 1756-EN2TRXT 1756-EN3TR, 1756-EN3TRK 1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT Support Parallel Redundancy Protocol (PRP) 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT 1756-EN4TR(1) , 1756-EN4TRK (1) , 1756-EN4TRXT(1) (1) 1756-EN4TR supports PRP with revision 4.001 and higher firmware. Support redundant adapters (2) (2) Redundant adapters require version 3.x and higher firmware. 1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT Provide control in environments where temperatures range from -25...+70 C (-13...+158 F) 1756-EN2TPXT 1756-EN2TRXT 1756-EN2TXT 1756-EN4TRXT Secure access to a control system from within the plant network 1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT Table 1 - ControlLogix EtherNet/IP Connections Specifications (1) (1) There are 1000 CIP I/O connections and 528 CIP messaging connections. Cat. No. Connections CIP Unconnected Messages (backplane + Ethernet)TCP CIP (2) (2) CIP connections can be used for all explicit or all implicit applications. For example, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections. 1756-ENBT 64 128 64 + 64 1756-EN2F 128 256 128 + 128 1756-EN2T 128 256 128 + 128 1756-EN2TP 128 256 128 + 128 1756-EN2TR 128 256 128 + 128 1756-EN3TR 128 256 128 + 128 Please contact me get more information Email:Mia@cwlyautomation.com VK/Whatsapp/Telegram:+8613667120925 Website: www.cwlyautomation.com