FOXBORO FBM241 Voltage Monitor Invensys Process System PLC

Published at 2024-08-29 3:05 AM
FOXBORO FBM241 Voltage Monitor Invensys Process System PLC Termination Assy Features 8 discrete inputs 8 discrete outputs Supports discrete inputs/output signals at voltages of: 15 to 60 VDC 120 VAC/125 VDC 240 VAC Each input and output is galvanically isolated: group isolated when used with external excitation Compact, rugged design suitable for enclosure in Class G3 (harsh) environments Executes the Discrete I/O or Ladder Logic program, with the following configurable options: Input Filter Time, Fail Safe Configuration, Fail-Safe FallBack, and Sustained or Momentary Outputs Various Termination Assemblies (TAs) that contain: Current limiting devices Fuses Relay outputs Relay outputs with internal or external power source and fusing Solid state outputs Please contact me get more information Email:Mia@cwlyautomation.com VK/Whatsapp/Telegram:+8613667120925 Website: www.cwlyautomation.com Overview The Compact FBM241, FBM241c, and FBM241d each have eight discrete inputs and eight discrete outputs. The Compact Channel Isolated, Discrete I/O Interface Modules (Compact FBM241/c/ d) have eight discrete input channels and eight discrete output channels. Associated termination assemblies (TAs) support discrete input or output signals at voltages of under 60 VDC, 120 VAC/125 VDC, or 240 VAC. Depending on the type of I/O signal required, the TAs contain current limiting devices, fuses, relays, or relay outputs with internal or external power source and fusing Each type of Fieldbus Module (FBM), without signal conditioning, uses a 15 to 60 VDC input or output signal. Each discrete input and output is galvanically isolated from other channels and ground. When used with external excitation, each discrete input and output is group isolated. The module performs signal conversion required to interface electrical input signals from field sensors to the optionally redundant fieldbus. It executes the Discrete I/O or Ladder Logic program, with the following configurable options: Input Filter Time, Fail Safe Configuration, Fail-Safe Fall-Back, and Sustained or Momentary Outputs. If the Momentary Output configuration is selected, then Pulse Output Interval is also configurable. More models Foxboro FBM201 Foxboro FBM217 Foxboro FBM203 Foxboro FBM204 Foxboro FBM206 Foxboro FBM207C Foxboro FBM207 Foxboro FBM207B Foxboro FBM202 Foxboro FBM224 Foxboro FBM215 Foxboro FBM241C Foxboro FBM242 Foxboro FBM231 Foxboro FBM228 Foxboro FBM233 P0926GX Please contact me get more information Email:Mia@cwlyautomation.com VK/Whatsapp/Telegram:+8613667120925 Website: www.cwlyautomation.com